Corrective Actions completed |
Corrective Actions Response
Independently Contracted Audit (135948) |
|
|
Audit ID# |
135948 |
Audit Type: |
Cooling and Cold Storage v08.06 |
Audit Score: |
96% |
Audit Started: |
12/16/2010 09:00 |
Audit Finished: |
12/16/2010 11:30 |
Auditor Name: |
Steven Hoak |
Entity List: |
Customer: Facility: Contact: Gary Hinton
|
Produce List: |
Strawberries, Squash, Beans, Snap, Blueberries, Peppers |
|
ALERTS & DISCLAIMERS
1) Please be aware that this service is provided for storing the data and does
not mean the corrective action comments will be reviewed by PrimusLabs.
2) When stating that a question's corrective action(s) has/have been "fully completed", please note that this must
mean that the corrective actions have been completed in full, not partially completed.
3) Please note that when you complete this corrective action form online customers and buyers are able to
access some or all of your corrective action responses.
4) Please be aware that customers and buyers are able to stipulate the type and level of corrective action data
they wish to see. Many customers/buyers only see partial/no completion of corrective action comments and uploads
i.e. they do not see any comments or uploads associated with "fully completed" responses. This means that any
"fully completed" must equate to full completion of a corrective action and not a partially completed action.
|
|
Severity Level: C - Good Manufacturing Practices |
Question 1.4.1 Are all exposed materials (product, packaging etc.) protected from overhead contamination (e.g. ladders, motors, condensation, lubricants, walkways, loose panels, degrading insulation, etc.)? |
Answer: Major Deficiency |
Auditor Notes: Attention to the blown insulation in coolers that is subject to degradation. |
Answer: We will partially complete or not complete corrective action(s) |
Comments:
|
|
|
|
|
Severity Level: C - Good Manufacturing Practices |
Question 1.6.3 Does equipment design and condition (e.g. smooth surfaces, smooth weld seams, non-toxic materials, no wood) facilitate effective cleaning and maintenance? |
Answer: Major Deficiency |
Auditor Notes: Attention to wooden guides in forced air coolers used for keeping pallets straight. |
Answer: We will fully complete the corrective action(s) by 09/01/2011 (mm/dd/yyyy) |
Comments:
|
|
|
|
|
Severity Level: C - Good Manufacturing Practices |
Question 1.9.1 Are all lights in the production, product storage areas, packaging storage areas and maintenance shops intact and protected? |
Answer: Major Deficiency |
Auditor Notes: Dock lights and about 10% of the lights on forklifts were not protected. |
Answer: We have fully completed the corrective action(s) |
Comments:
|
|
|
|
|
Severity Level: C - Good Manufacturing Practices |
Question 1.9.8 Are doors to the outside pest proof? |
Answer: Minor Deficiency |
Auditor Notes: Doors have cracks, which can allow pests to enter the facility. |
Answer: We will fully complete the corrective action(s) by 03/01/2011 (mm/dd/yyyy) |
Comments:
|
|
|
|
|
Severity Level: C - Good Manufacturing Practices |
Question 1.9.11 Are exterior walls free of holes to exclude pests? Are pipes, vents, air ducts designed and protected in order to prevent pest entry e.g. by using fine mesh? |
Answer: Minor Deficiency |
Auditor Notes: Attention to holes in the walls of the dry storage area. |
Answer: We will fully complete the corrective action(s) by 05/01/2011 (mm/dd/yyyy) |
Comments:
|
|
|
|
|
Severity Level: C - Food Security |
Question 3.1.1 Are the facility external areas and vulnerable entry points (i.e. those that are not permanently locked) surrounded by security fencing? |
Answer: Non-Compliance |
Auditor Notes: No. The facility does not have security fencing. |
Answer: We will partially complete or not complete corrective action(s) |
Comments:
|
|
|
|
|
Severity Level: C - New Questions ( Not part of overall Food Safety percentage) |
Question 5.1.7 Are all cuts and wounds covered with waterproof detectable blue bandages (Band Aids) that contain a metal strip? |
Answer: Non-Compliance |
Auditor Notes: No. Blue bandages with metal strips are not being used. |
Answer: We have fully completed the corrective action(s) |
Comments:
|
|
|
|
|
Audit Representative Contact Details
Author's Name: Jacob Raburn
Company Position: Food Safety Director
Phone Number: 813-763-2968
Email Address: jake@hintonfarms.com
|
|
|