These Corrective Actions are not completed yet, please complete your corrective actions
Do you want to edit your Corrective Actions?
Corrective Actions Response
Independently Contracted Audit (74697)
   
Audit ID#  74697
Audit Type:  Cooling/Cold Storage v05.06
Audit Score:  96%
Audit Started:  12/10/2007 10:35
Audit Finished:  12/10/2007 12:45
Auditor Name:  Steven Hoak
Entity List:  Customer:
      
Facility:
      
      Contact: Gary Hinton
Produce List:  Strawberries, Squash, Blueberries, Peppers
 
ALERTS & DISCLAIMERS

1) Please be aware that this service is provided for storing the data and does not mean the corrective action comments will be reviewed by PrimusLabs.

2) When stating that a question's corrective action(s) has/have been "fully completed", please note that this must mean that the corrective actions have been completed in full, not partially completed.

3) Please note that when you complete this corrective action form online customers and buyers are able to access some or all of your corrective action responses.

4) Please be aware that customers and buyers are able to stipulate the type and level of corrective action data they wish to see. Many customers/buyers only see partial/no completion of corrective action comments and uploads i.e. they do not see any comments or uploads associated with "fully completed" responses. This means that any "fully completed" must equate to full completion of a corrective action and not a partially completed action.


 
Severity Level: C -  Good Manufacturing Practices
Question 1.1.3 Are "food grade" and "non food grade" chemicals handled and stored in a controlled manner?
Answer: Minor Deficiency
Auditor Notes: Food grade and non-food grade chemicals are not stored separately in the locked storage room.
Answer: 
 
 
Severity Level: C -  Good Manufacturing Practices
Question 1.3.2 Is the storage area completely enclosed?
Answer: Minor Deficiency
Auditor Notes: The dry storage area is not completely enclosed. All cold storage is completely enclosed.
Answer: 
 
 
Severity Level: C -  Good Manufacturing Practices
Question 1.6.2 Are non-food contact surfaces free of flaking paint, corrosion, rust and unhygienic materials (e.g. tape, string cardboard etc.)?
Answer: Minor Deficiency
Auditor Notes: Coolers have blown insulation that is subject to degrading and falling on product.
Answer: 
 
 
Severity Level: C -  Good Manufacturing Practices
Question 1.7.4 Are all fan guards dust-free and the ceiling in front of the fans free of excessive black deposits?
Answer: Major Deficiency
Auditor Notes: High-level in front of fan guards appear dusty.
Answer: 
 
 
Severity Level: C -  Good Manufacturing Practices
Question 1.7.7 Are excess lubricants and grease removed from the equipment?
Answer: Minor Deficiency
Auditor Notes: Equipment had some excess grease.
Answer: 
 
 
Severity Level: C -  Good Manufacturing Practices
Question 1.8.12 Is the maintenance shop organized - i.e. equipment and spares stored in a neat and tidy fashion?
Answer: Minor Deficiency
Auditor Notes: Maintenance area did not appear to be organized.
Answer: 
 
 
Severity Level: C -  Good Manufacturing Practices
Question 1.8.13 Are internal transport vehicles (e.g. forklifts, bobcats, pallet jacks, trolleys, floor cleaners etc.), clean and being used in a sanitary manner?
Answer: Minor Deficiency
Auditor Notes: Forklifts were dirty.
Answer: 
 
 
Severity Level: C -  Food Safety File Requirements
Question 2.2.1 Are copies of all Materials Safety Data Sheets (detergents, sanitizers, pesticides, etc.) on file and fully accessible at all times with clear indexes?
Answer: Minor Deficiency
Auditor Notes: All MSDS are not kept on file.
Answer: 
 
 
Severity Level: C -  Food Safety File Requirements
Question 2.7.1 Are there records of equipment microbiological testing?
Answer: Non-Compliance
Auditor Notes: No, equipment microbiological testing is not done.
Answer: 
 
 
Severity Level: C -  Food Safety File Requirements
Question 2.7.2 Are there records of environmental microbiological testing?
Answer: Non-Compliance
Auditor Notes: No, environmental microbiological testing is not done.
Answer: 
 
 
Severity Level: C -  Food Security
Question 3.1.1 Are the facility external areas and vulnerable entry points (i.e. those that are not permanently locked) surrounded by security fencing?
Answer: Non-Compliance
Auditor Notes: No, the facility does not have security fencing.
Answer: 
 
 
Severity Level: C -  New Questions - Not part of overall percentage
Question 5.1.4 Are the SOP's available to relevant users and also a master copy maintained in a central file (SOP Manual)?
Answer: Non-Compliance
Auditor Notes: No, SOP's are not currently available to relevant users.
Answer: 
 
 
Audit Representative Contact Details
Author's Name:
Company Position:
Phone Number:
Email Address:

Do you want to edit your Corrective Actions?