Report & Corrective Action Summary
 
Audit #: 114056 Audit Type: Cooling and Cold Storage v08.06    Customer: Hinton Farms Produce, Inc.
Audit Date: 12/09/2009 Auditor: Steven Hoak  
Audit Score: 98% Contact Person: Audra Hinton; audra@hintonfarms.com  
Product(s): Strawberries,Squash,Beans, Snap,Blueberries,Peppers
Category
Question
Number
Question
Possible
Points
Given Answer
Given
Points
Auditor Comment
Corrective Action Response
Corrective Action Comment
Good Manufacturing Practices
1.3.2
Is the storage area completely enclosed?
10
Minor Deficiency
7
The dry storage area and packing area had doors that were left open during work hours, but all cold storage areas are completely enclosed.
We will partially complete or not complete corrective action(s)
We intend to determine a way of keeping the operational doors of the packing facility covered during use. These doors are currently kept closed at all times, when not in use.
Good Manufacturing Practices
1.4.1
Are all exposed materials (product, packaging etc.) protected from overhead contamination (e.g. ladders, motors, condensation, lubricants, walkways, loose panels, degrading insulation, etc.)?
15
Minor Deficiency
10
Attention to the blown insulation in coolers that is subject to degradation.
We will partially complete or not complete corrective action(s)
The insulation in our coolers is regularly painted and maintained in order to prevent any contamination. This is an ongoing preventative maintenance policy for our facility. There has not been a contamination issue to date.
Good Manufacturing Practices
1.9.8
Are doors to the outside pest proof?
5
Minor Deficiency
3
Doors have gaps, which can allow pests to enter the facility.
We will fully complete the corrective action(s)
We will replace and/or add seals to exterior doors in order seal doors completely.
Good Manufacturing Practices
1.9.12
Are interior walls and ceilings free of cracks and crevices to prevent pest harborage and allow proper sanitation?
5
Minor Deficiency
3
Attention to holes created by corrugated panels around the base of the facility.
We will fully complete the corrective action(s)
We will thoroughly examine this area of the facility utilizing a light differential test to determine if there are any holes along the base of the building. If a hole is found, it will be repaired immediately in order to maintain the integrity of the building.
Food Safety File Requirements
2.5.5
Is there a program for periodic facility/GMP internal (self) inspections and are records maintained detailing corrective actions?
10
Minor Deficiency
7
Only one month of records was on file.
We will fully complete the corrective action(s)
We have changed our policy in order to more accurately internally inspect our facility. Although the new policy is already in place, we will have three months of records to reflect this change by February 2010.
Food Safety File Requirements
2.5.7
Is there a program for periodic inspections of food safety system records e.g. pest control records, temperature control records, sanitation records, maintenance records, etc?
5
Minor Deficiency
3
Only one month of records was on file.
We will fully complete the corrective action(s)
We have changed our policy in order to more accurately internally inspect our food safety paperwork. Although the new policy is already in place, we will have three months of records to reflect this change by February 2010.

Audit Scoring Summary
Good Manufacturing PracticesScore586
Possible Points598
Percent Score98%
Food Safety File RequirementsScore289
Possible Points294
Percent Score98%
Miscellaneous Survey QuestionsScore0
Possible Points0
Percent Score0%
TotalScore875
Possible Points892
Percent Score98%

Food Security Scoring Summary
Food SecurityScore99
Possible Points99
Percent Score100%
TotalScore99
Possible Points99
Percent Score100%

New Questions Scoring Summary (Not Part Of Overall Food Safety Percentage)
New Questions ( Not part of overall Food Safety percentage)Score20
Possible Points20
Percent Score100%
TotalScore20
Possible Points20
Percent Score100%

Point System For Individual Questions
Question Points Total
Compliance
Minor
Deficiency
Major
Deficiency
Non
Compliance
15 Point Question 15 points 10 points 5 points 0 points
10 Point Question 10 points 7 points 3 points 0 points
5 Point Question 5 points 3 points 1 point 0 points
3 Point Question 3 points 2 points 1 point 0 points